EdilKamin QUEBEC Instalación Uso Y Mantenimiento página 49

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
Should ignition fail, DO NOT re-ignite until you have emptied the combustion chamber.
Regular maintenance is required for the thermo-stoves to function correctly.
The thermo-stoves will trigger the message: 'smoke °C/high' or 'Mainten.' to appear on the panel when further cleaning is
necessary.
FAILURE TO PERFORM at least SEASONAL MAINTENANCE can cause the thermo-stoves to malfunction and any pro-
blems deriving from this will not be covered by the warranty.
Non-compliance with maintenance procedures will render the warranty null and void.
Before performing any maintenance, disconnect the appliance from the mains.
Weekly cleaning (see illustration on next page)
Cleaning should be carried out with the aid of a vacuum cleaner (see optional page. 53).
Operation to be carried out when the stove is cold.
Never vacuum hot ashes, as this would damage your vacuum cleaner.
• Vacuum the door and if necessary clean the glass (cold).
• Open the small door and remove and empty the ash tray (Fig. A-1) vacuum the fire bed.
• Remove the front tile (Fig. B-2).
• Vacuum the crucible or scrape it with the spatula provided, clear any obstructions from the holes on all sides, after removing the
front plate (fig. C -3).
• Clean the spark plug
• Remove the inspection plugs on both sides of the hearth and vacuum the crucible (Fig. D-4).
• Move the cleaning rods (*) :
- For the Quebec/Toronto models, remove the ceramic top and make movements with the lever (see fig. E).
- For the Ottawa model, remove the metal top and make movements with the lever (see fig. F).
- For the Montreal/Miami models, open the top door and act on the lever (see fig. G).
• Following a period in which the stove has been inactive and in any case at least every month, empty the pellet storage tank and vacuum the bottom.
NOTE: The DEALER, upon commissioning, sets the kg value of consumed pellets; after which, the message "SERVICE UTE" will
appear on the display. The thermo stove continues operation, but the end client is invited to perform careful maintenance, descri-
bed above and explained by the DEALER during commissioning, to the extent of his abilities. To eliminate the message from the
display, press the boiler button for at least 5 seconds after having completed maintenance.
Seasonal cleaning (implemented by the dealer)
The DEALER, upon commissioning, sets the kg value of consumed pellets; after which, the message "Mainten." will appear on the display.
The thermo stove continues operation, but the end client must contact the DEALER to perform necessary seasonal maintenance. The end client
is invited to perform seasonal maintenance regardless of which messages may appear on the display.
Before performing any maintenance, disconnect the appliance from the mains.
The Dealer will provide you, on the occasion of the first start up, with the stove maintenance book, where the steps for seaso-
nal cleaning, outlined here below, are listed.
• Clean the thermo-stoves internally and externally
• Carefully clean the heat exchange tubes
• Carefully clean and remove dirt from the combustion chamber and the relative compartment
• Clean the motors, verify mechanical and clam loosening
• Clean smoke channel (replace seals on pipes) and smoke extraction fan chamber
• Check the expansion tank
• Check and clean the circulator
• Check the sensors
• Check and if necessary replace the clock battery on the control board
• Clean, inspect and scrape any residue from the ignition resistance compartment and if necessary, replace it
• Clean/check the Synoptic Panel
• Visually inspect the electrical wires, connections and power cable
• Clean the pellet hopper and check loosening of the feed screw - gear motor assembly
• Check and if necessary replace the door seal
• Functionality test: load the feed screw, ignite, let it run for 10 minutes and shutdown
If maintenance if not implemented, the warranty will be rendered null and void.
If the thermo-stoves is used very often, it is recommended to clean the smoke channel every 3 months.
When maintenance is implemented in the smoke channel, consider UNI 10847/2000 Individual chimney installations for generators
running on liquid and solid fuel. Maintenance and control.
The chimney stacks and smoke ducts to which solid fuel appliances are connected should be cleaned once a year (verify whe-
ther in there are regulations in force in your country regarding this)
In the even that regular checks and cleaning are not performed the probability of a chimney fire increases.
In the event of such an occurrence proceed as follows: do not extinguish with water; empty the pellet storage tank; contact the
Dealer before re-starting after such an incident.
MAINTENANCE
49

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

TorontoMontrealOttawaDetroitBostonMiami ... Mostrar todo

Tabla de contenido