INSTALLATION
For anything that is not specifically stated herein, each country should refer to the applicable local regulations. In
Italy, refer to standard UNI 10683/2005 in addition to any regional instructions or local health authority instruction.
CHECKING COMPATIBILITY WITH OTHER DEVICES
The insert must NOT be installed in the same room as type B gas appliances, extractors, etc.
See chap. 4.1 of standard UNI 10683/2005.
CHECKING ELECTRICAL CONNECTION
INPELLET 54 is supplied with an electrical power lead to be connected up to a 230V 50 Hz socket and preferably
with a thermal magnetic switch.
Changes in voltage by more than 10% can affect the insert (if not already in place, use an appropriate differential
switch).
The electrical system must be certified as legally compliant. Specifically check the efficiency of the earth circuit.
The power line must be of a section that is appropriate to the insert power.
An inadequate earthing system can cause anomalies for which Edilkamin cannot be held liable.
SAFETY DISTANCE FOR FIRE-PREVENTION AND POSITIONING
To function correctly, INPELLET 54 must be positioned on the level.
Check that the floor load capacity is sufficient.
INPELLET 54 must be installed in compliance with the following safety conditions:
- leave a minimum of 40 cm space to the sides and back from any medium-flammable materials
- leave a minimum of 80 cm space to the front from any medium-flammable materials
If it is impossible to leave the distances given above, technical and construction provisions must be taken to avoid
all fire risk.
If connected to a wooden wall, or wall constructed from another flammable material, the smoke exhaust pipe and
other hot parts must be insulated with ceramic fibre or other, similar materials, to prevent heat transmission and
resulting fire hazards.
AIR INTAKE
An air intake must be prepared behind the insert and connected with the outside. It must have a useful minimum
section of 80 cm² to guarantee sufficient air to the insert for combustion, without creating depression in the instal-
lation room.
A 5 cm diameter outlet is found on the rear of the INPLELLET 54.
This outlet is used for air intake connected directly with the outside via pipes.
The pipes must not be longer than 1 metre and have no bends and must have a wind guard at the end.
Note: Even in the case of direct connection, an air inlet which connects the installation room with the outsi-
de must be set.
23