USER'S MANUAL. PROLITE-40
1.2
Terms about Fusion splicer
During operating the fusion splicer by menu, you will find some terms, the
meanings are as follows:
Heat time:
Surface angle:
Push:
Push speed:
Pre-fusion:
Fusion:
Fusion push:
Gap:
Calibration
Test
Cleaning
electrode:
02-2011
Sets up heat time. (Unit: 30 Seconds).
Allowed maximum cleaved slope angle when machine
checking the end-face.
Process that electromotor drives fiber to move forward
during splicing.
The electromotor controls delay of unit during arc
splicing, while push speed slower, the moving speed of
fiber becomes faster.
Process that arcs little current while doesn't push fiber
during splicing.
Process that arcs proper current and pushes fiber during
splicing.
The quantity of pushing fiber during splicing.
Space between left and right fibbers end-face that set up
by before splicing..
Process that adjusts the warp between left and right fiber
to make them are collinear during splicing.
Arcs to revise arc position and arc current automatically.
Part high temperature gasifies the impurity on electrode's
surface during arc.
Table 1.-