Idiomas disponibles

contact the Dri-Eaz Service Department at
800-932-3030 or 360-757-7776.
CAUTION: Dust can cause the unit to overheat and
shut down. Do not operate when excessive dust or
airborne particles are present, such as during
sanding or spray-painting. Inspect and clean air filter
elements and coils frequently.
IMPORTANT: Replace the HAF filter whenever 1)
it has been vacuumed clean 3 times or 2) it has
been used on a mold remediation job or
otherwise exposed to potentially dangerous
contaminants.
Monthly
Check coils. Dirty coils can cause the unit to overheat.
Clean when visibly dirty. See "Instructions for Cleaning,"
p. 7.
Check heat exchange block. Clean out with
compressed air only. Take care not to damage the block.
Inspect and clean the pump. To remove the
condensate pump unit:
1. Unplug unit and remove cord.
2. Remove the five screws that hold in the lower back
metal panel and the two bolts that secure the bottom
of the polyethylene back panel (see Fig. D).
3. Detach both inlet and outlet hoses from pump.
4. Remove pump mounting bracket (1 screw).
5. Rotate pump horizontally to the right, then tip
upward, taking care to avoid the metal junction box
above. Pull the pump out of the unit, and then
disconnect the electrical cable.
07-01674B 2009-04
5. Place the pump on a sturdy surface. Lift the white
plastic pump housing upward off the black plastic
water collection container. Use a soft, absorbent cloth
to wipe out any debris inside the container. Replace
the pump housing on the container, and make sure it
is squarely seated.
6. To reinstall the pump, follow these instructions in
reverse.
Annually
Have the pump system inspected by the Dri-Eaz Service
Department (800-932-3030) or by a qualified service
center.

TRANSPORT AND STORAGE

NOTICE: Handle the unit carefully. Do not drop,
throw, or place the unit where it could fall. Rough
treatment can damage this equipment and may
create a hazardous condition or void warranty.
IMPORTANT: Before moving the unit, make sure
there is no water in the pump's reservoir. Press the
PURGE button on the control panel to empty
reservoir. (See the PURGE function under "How to
use the control panel" on page 4.)
1. Do not expose the control panel to moisture, snow or
rain when transporting in uncovered vehicles such as
flatbed trucks.
2. Store and transport securely to avoid any damaging
impact to internal parts.
READ AND SAVE THESE INSTR