Windbreak.
Stainless steel hose clamp.
T of 135° with outlet.
Elbow of 45°.
Insulator.
Wooden ground.
Non flammable floor protection.
Elbow of 90°.
*Distance equal to or over 2 metres.
1(
MAXIMUM 1 metre.
4.25. When fitting stoves in brickwork chimneys a perfect seal between the flexible and the rigid pipe must be
achieved. Similarly, the insulation to be placed at the contact areas between the pipe and possibly
inflammable zones must be taken into account. The tube end may be left inside the chimney itself, taking
into account its opening.
Special attention must be paid to the cleaning of the chimney, especially if the latter has been used in a
fireplace or wood stove. If this is the case, we highly recommend the whole conduct to be thoroughly
cleaned in order to prevent a small fire from starting.
Once installation is complete, we must seal the chimney from the inside of the house.
Stainless steel hose clamp.
T of 135° with outlet.
Elbow of 45°.
Wooden ground.
Non flammable floor protection.
Stainless steel flexible tube.
Rigid flexible pole adapter.
Minimum 200mm.
It must exceed roof height by 1 metre.
If the tube over 4 m in length, the next larger
size will be used.
4.26. Installing a fitted stove in a brickwork chimney can be done using flexible piping in its entirety, as indicated in
drawing 10. We must take special care when sealing the chimney and gas venting to avoid gas blowing back
during storms.
32
Drawing 8