THE GAS OUTLET EXTRACTOR DOES NOT WORK OR DOES NOT WORK CORRECTLY:
6.18. Make sure the motor rotates properly by rotating it with your hand (the stove should be disconnected to do
so).
6.19. Check that power reaches the motor, by turning the stove on.
6.20. Also check the exhaust connection strip and the C.P.U.
THE CONVECTION FAN DOES NOT ROTATE:
6.21. Make sure that the turbine is not stalled by unplugging the stove. Then access to the right side and rotate it
with your hand to ensure that it rotates perfectly.
THE STOVE TURNS OFF:
6.22. There might be no pellets in the stove.
6.23. A forgotten set programme might have stopped the stove.
6.24. A bad quality of pellets, humidity can be causes of unexpected stops.
6.25. If the stove turns off and there are half burnt pellets in the burn pot, this might be due to a lack of cleaning.
Revise chapter related to cleaning and maintenance.
6.26. Internal dirt or ongoing use without cleaning.
6.27. If the stove is off and there are no pellets in the burn pot, check the reducer motor, convection motor and
extractor.
ALARM IN TABLET / DISPLAY KEYBOARD:
Revise paragraph 5 (Alarms) in user manual.