Connectors
X1A
X1B
X2
Wire sizes and tightening torques:
X1A: Dinkle EC762V-B3253206P-BK
X1B: Dinkle EC762V-B3253203P-BK
2
0.2...6.0 mm
(30*...10 AWG)
* Minimum size for UL installations is 14 AWG.
Torque: 0.7 N·m (6.2 lbf·in)
X2: Phoenix Contact MVSTBR 2,5HC/ 2-ST-5,08
2
0.2...2.5 mm
(24...12 AWG)
Torque: 0.6 N·m (5.3 lbf·in)
X3, X4: Weidmüller B2L 3.50/20/180,
Weidmüller B2L 3.50/8/180
2
0.2...1.0 mm
(28...16 AWG)
Notes:
The wiring shown is for demonstrative purposes only.
Complete information for all connectors, including X7
and X8, is provided in MicroFlex e190 User's Manual
(code: 3AXD500000373236).
Quick installation guide - MicroFlex e190
E2
Ethernet fieldbus
E1
E3
Ethernet host (PC)
X3
Input/ Output
X4
Safe Torque Off
X8
Universal encoder input
supports multiple
feedback types.
See MicroFlex e190
User's Manual.
Optional 24 V supply
Incremental encoder
X7
in/out
SW2
X8 voltage selector
using external
Ethernet fieldbus
115...240 V AC ±10%
input
DC bus-
Brake resistor
DC bus+ / Brake res.
Motor output
Ethernet host (PC)
X3
Status-/DO0-
1
2
DO2-
3
DO1-
4
DI2-
5
DI3-
6
DI1-
7
DI0-
8
AGND
9
AI0-
10
Shield
X4
STO1
1
2
STO2
3
SGND
Example:
STO input
4
24 V out
24 V supply
Safe Torque Off: Both circuits must be closed for the drive to start.
All connections are duplicated for easy wiring.
(Optional) External
power input: 24 V, 1 A
E1/E2
IN
E2
E1
OUT
X1A
L1
1
L2
2
L3
3
4
UDC-
5
R-
6
R+/UDC+
X1B
U
1
V
2
W
3
E3
1
X3
Status-/DO0+
11
DO2+
12
DO1+
13
DI2+
14
DI3+
15
DI1+
16
DI0+
17
AO0
18
AI0+
19
Shield
20
X4
STO1
11
STO2
12
SGND
13
24 V out
14
X2
0 V
1
+24 V IN
2
M
Example:
STO input
using internal
24 V supply

Publicidad

Tabla de contenido
loading

Tabla de contenido