Adjustment Of The Power And Operational Times; Control Unit Indicators (Leds) - V2 FLEXY2 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
ADJUSTMENT OF THE POWER AND
OPERATIONAL TIMES
The power and operating times may be adjusted by means of 4
trimmers located on the control unit:
m
PLEASE NOTE: it is recommended that operating times
be set with the slow down function disabled (DIP 5 OFF).
m
WARNING: the adjustment of times has to be made
when the gate is still
MIN
MAX
POWER

CONTROL UNIT INDICATORS (LEDs)

The highlighted boxes indicate the state of the LEDs when the gate is resting.
LED
START
START P.
STOP
PHOTO
EDGE
Edge NO pressed: 8K2 between EDGE input and
FCA
FCC
mains
overload
18"
2"
45"
2"
WORK
2"
2"
50"
J1 closed
J1 opened
ON
START input closed
START P. input closed
STOP input closed
PHOTO input closed
EDGE input closed (edge not pressed)
EDGE input closed (edge pressed)
common (-)
Opening limit switch closed
Closing limit switch closed
Control unit powered-up
Accessory power supply overload
POWER:
motor power.
WORK: motor operating time
J1 closed = 2 - 50 seconds
J1 opened = 2 - 120 seconds
PAUSE: pause time before automatic re-closure
(2 - 150 seconds).
DELAY: time delay between the two gate leaves
(0 - 90 seconds).
30"
30"
90"
2"
WORK
PAUSE
2"
120"
J1 opened
J1 closed
Standard edge
Resistive rubber edge
Accessory power supply within normal operational limits
- 15 -
15"
90"
0
DELAY
0
150"
OFF
START input open
START P. input open
STOP input open
PHOTO input open
EDGE input open (edge pressed)
EDGE input open (fault)
Opening limit switch open
Closing limit switch open
Control unit NOT powered-up
45"
90"

Publicidad

Tabla de contenido
loading

Tabla de contenido