5 - DESCRIPTION OF THE CONTROL
UNIT
The digital control unit HEAVY2 is an innovative V2 product that
guarantees a safe and reliable automation of industrial sectional
doors.
In compliance with the European standards concerning electrical
safety and electromagnetic compatibility (EN 60335-1,
EN 50081-1 and EN 50082-1) it has been equipped with the low
voltage circuit total electric insulation (motors included) from the
network voltage.
Other characteristics:
• Multilingual programming menu through 122x32 pixel graphic
display
• Power supply for 1 x 230V/400V three-phase or 230V
single-phase motor
• Input for connection of an encoder
• Plug connector for modular MR radio receiver
• Start control, pedal start, stop by transmitter
• Two programmable relay outputs such as lights, electric lock,
warning light or functioning test 12Vdc
• 230V blinker output (use intermittent blinkers)
• Test of safety devices (photocells and ribb.) before each
opening
• Running self-learning function
• Obstacle detection function through amperometric sensor
• Operational cycle counter with programmable maintenance
requirement setting
• Monitoring of input status via display
• ADI connector for connection of the optional CL1+, WES-ADI
modules
6 - LANGUAGE SELECTION
The HEAVY2 unit, thanks to the graphic display, is able to display
messages in order to simplify the installation phases.
The pre-set language is ENGLISH but you can select an alternative
language.
To select another language, proceed as follows:
1. Power the unit
2. The display shows the firmware versions of micro-controllers,
serial number and language:
3. While the display shows
ENGLISH
display shows the alternative language (E.g.
4. Release the OK button: the new language has been set.
To upload a new language instead of ITALIAN it is necessary to use
the V2+ with the CL1+ accessory:
1. Load the file in the selected language on the CL1+ device
through the V2+ software
2. Cut off the power supply to the HEAVY2 unit
3. Insert the CL1+device into the ADI connector of the HEAVY2
unit
4. Power the HEAVY2 unit: the new language is downloaded and
automatically set
5. Remove the CL1+ device
ENGLISH
hold the OK button: the
)
ITALIAN
7 - CONTROL PANEL
When the power supply is turned on the display shows in
sequence the following information:
1. Firmware version of the micro-controller of the unit
2. Serial number
3. Current language set
Here following is the control panel:
i1
i2
The control panel (in standby mode) displays the
physical state of the contacts to the terminal board and
programming buttons:
ING1 input
I1
ING2 input
I2
ING3 input
I3
PHOTOCELL 1 input
F1
PHOTOCELL 2 input
F2
RIBB. 1 input
C1
RIBB. 2 input
C2
The dot displayed below the abbreviations of inputs
indicates the status of the input:
• FULL dot: contact closed
• EMPTY dot: contact open
In the upper part of the display the status of the
automation system is shown:
• The message (e.g. WAITING) indicates the status of the
unit
• The bar under the message indicates the position of the
gate with respect to the limit switch
• The dot to the left of the bar shows the closing limit
switch
• The dot to the right of the bar indicates the opening
limit switch
• The arrow on the left indicates the status of the device
connected to the terminal H3
• The arrow on the right indicates the status of the device
connected to the terminal H4
The dot of the limit switches and the arrows of the inputs
H3 and H4 indicate the input status:
• Arrow/FULL dot: closed contact
• Arrow/EMPTY dot: open contact
In the example shown above the display indicates that:
• The contact of F1 - F2 inputs is closed
• The contact of I1 - I2 - I3 - C1 - C2 inputs is open
• The gate is locked and in standby mode, waiting for a
command
- 29 -
WAITING
ATTESA
i3
f1
f2
c1
c2