Technical Specifications; Power Requirements - Truper COPLA-40 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical specifications

Voltage (automatic adaptation)
Open Circuit Voltage
Current Range
Maximum Cutting Capacity
Ideal Cutting Capacity
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
In the event of faults or breakdown ground connection supplies a
minimum resistance trajectory for the power supply, thus reducing the risk of electric
shock. This tool is equipped with a power cable, adapter and ground connection
sockets. Ground shall be connected into an outlet installed and grounded following all
the local codes.
WARNING
Do not modify the socket supplied. If the socket is not fit for
the outlet, have a certified electrician to install the appropriate outlet.
• If using the cutter together with more tools having the same ground, connect in parallel, never making a series.
CAUTION
• The ground conductor cable gauge shall not be a lower gauge than the power supply cable.
CAUTION
• Connection to the power supply shall be carried out by a professional electrician.
• Double check the input connection voltage shown in the plasma cutter nameplate matches the power
CAUTION
supply voltage.
• The power supply gauge
CAUTION
shall comply with the following requirements:
Code
Description
Frequency
Current
Work Cycle
Air Pressure
Weight
Insulation
Conductors
COPLA-40
17335
Plasma Cutter
INPUT
110 V
60 Hz
22 A / 30 A
OUTPUT
310 V c.c.
110 V : 16 A / 220 V : 20 A - 40 A
1/2"
3/8"
35 % 3,5 minutes' work per 6,5 minutes' rest.
The specified output values are given in a 68 °F temperature.
With higher temperatures, the work cycle can be reduced.
55 PSI -70 PSI
14.7 lb
Class I
12 AWG x 2 C with 221 °F insulation temperature
Power Cord Grips used is: Type "Y".
Tool Build Quality: Basic Insulation
Thermal insulation on motor winding: Class H
Authorized Service Center.
Switch
Fuse (rated working current)
Electric Wire
* Fuse fusion current is double than its rated current.
/ 220 V
IP Grade
IP21S
30 A
30 A ( * )
2,5 mm
2
ENGLISH
3
3

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

17335

Tabla de contenido