Appliance Specifications - De Dietrich MPLC 150 Manual De Instalación, Puesta En Servicio Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3 Technical specifications
3

Appliance specifications

Tank type
Water capacity
Exchanger interior volume
Exchange surface
Electrical power of the immersion heater
30-mA differential circuit breaker
Heating time ("Electric" 10 - 65°C)
Forced circulation - Primary at 90°C flow rate 2 m3/h
Power exchanged
Continuous flow
Max. flow over 10 mn (60°C storage)
Heating time (10- 60°C)
Forced circulation - Primary at 60°C flow rate 2 m3/h
Power exchanged
Continuous flow
Max. flow over 10 mn (60°C storage)
Heating time (10- 50°C)
Thermosiphon - Primary at 90°C
Power exchanged
Continuous flow
Max. flow over 10 mn (60°C storage)
Heating time (10- 60°C)
Maintenance consumption at 65°C
Weight
(1) The performance levels above apply to tanks in the vertical position. Allow a 10% reduction for horizontal installations.
(2) Thermosiphon: the performance levels are given for a non-resistant installation (ø 1"1/4) with 4 bends, the bottom of the
water heater being at least 2 m above the boiler.
(3) Domestic cold water at 10°C - Domestic hot water at 45°C.
38
(1) (3)
(1) (3)
(1) (2) (3)
MPL
Max. temperature
Max. pressure
Unit
l
l
W
A
h
kW
l/mn
l/10 mn
mn
kW
l/mn
l/10 mn
mn
kW
l/mn
l/10 mn
mn
kWh/24h
kg
Tank
Exchanger
90°C
100°C
6 bar
3 bar
Warning:
The operating pressure of the heat exchanger circuit must not
exceed 3 bar - 0.3 MPa, and its temperature must not exceed
100°C.
MPLC 150
MPLC 200
150
200
7.7
10
0.95
1.2
2200
2200
16
16
3h35
4h45
26
29
10.7
11.8
235
302
30
30
8.8
9.7
3.6
4
163
214
95
95
17.5
19.2
7.1
7.8
217
282
50
50
1.62
2.16
51
62
76249662 - v02 - 24032016

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mplc 200

Tabla de contenido