TDB3108, WF3208
Adaptive Infrared Assembly for B Drain and H Drain Units with
4b
Tie Pipe Option continued...
Place the infrared module assembly on top of
D
sprayhead . Rotate until infrared module locks in
with tie bar . Drop two infrared module wires down
to valve assembly .
Skip to step F for units without soap.
E
For units with soap option, slide the spacer and
soap dispenser over the 1-1/2" pipe .
Position the upper tie bar slightly below the module
F
or soap dispenser and fasten securely to vent pipe
with set screws provided . Secure top cover to tie
bar with two cap screws provided .
For B Unit: Install 1/2" nominal copper tubing
G
supply lines (pass them through holes in cover
down through support column) and connect supply
lines to stops using suitable fittings .
14
4/30/2013
Unit with "B" Drain and I.R. Module
Shown, Also Available with "H" Drain
Soap
Dispenser
Module
Cover
Tie Bar
Support Tube
Std . (S57-005)
Juv . (S57-006)
Bradley • 215-1187 Rev. P; ECN 13-00-001
Installation
Top
Cover
Spacer
Infrared Module
Assembly (S50-344)
Sprayhead