Installation
5

Valve and tubing connections

Flush supply lines before making connections.
Do not apply pipe sealant to compression fittings.
A
Connect 1/2" dia . tubing to tee and solenoid
assembly, two places . The male connector
for the valve assembly will remain tight and
leakproof when tubing is cut and installed
properly . Follow the procedures below when
installing tubing to ensure that you achieve a
leakproof seal .
• Using a sharp razor, cut tubing squarely
and remove any burrs . DO NOT pinch or
crush end of tubing .
• Loosen nut on fitting . Moisten end of tube
and push into fitting until it is firmly seated .
Tighten nut to secure tube to fitting (make
sure nut is securely tightened) .
• If connector leaks, reseat tubing according
to above procedure . If leaking persists,
replace male connector, or call your
Bradley representative for assistance .
B
Hang valve assembly on pedestal bracket .
Use wire tie to secure valves .
For "O" and "B" units (overhead
supplies) skip steps C through E.
C
Connect the 1/2" NPT female end of the
stop/check valves to the rough-ins .
D
Attach flexible hosing to thermostatic mixing
valve, two places .
Insert the filter washers (provided) into the
E
swivel nut at the end of the supply hoses and
connect to the stop/check valves .
Bradley • 215-1187 Rev. P; ECN 13-00-001
1/2" Dia . Tube
(R68-600012)
Solenoid
Assembly
(S08-055)
Flexible
Hose
Filter
Washer
Stop/Check
Valve
Pedestal
Valve Bracket
Volume
Control
Check/Stop
Valve
TDB3108, WF3208
1/2" Dia . Tube
from Sprayhead
Tee
(269-764)
Volume Control
(S02-045)
Thermostatic
Nut
Male Tube
Connector
1/2" Tube from
Sprayhead
Hot Supply
4/30/2013
Mixing Valve
Assembly
(S67-597)
Tubing
Filter
Washer
Cold Supply
15