Troubleshooting - Truper SCI-10 Manual De Instrucciones

Sierra de cinta
Ocultar thumbs Ver también para SCI-10:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Electric connection diagram
WARNING
BEFORE GAINING ACCESS TO TERMINALS ALL
FEEDING CIRCUITS SHALL BE DISCONNECTED.
Below are the electrical diagrams to make the motor connections according to the supply voltage.
Problem
Cause
The machine is not
• No power supply.
running when turned
• Defective power cord.
on.
The band is not
• The band tension knob is not tight.
moving and the
motor is running.
• The band got loose from the flywheels.
• The saw band is broken.
• The direction band is broken .
The band is not
• The support fence is not being used.
cutting in a straight
• The feeding rhythm is too fast.
line.
• The band teeth are dull or damaged.
• The band guides are misadjusted.
The band is not
• Teeth are dull.
cutting or cuts slowly.
• The band is mounted backwards.
The band is not
• This is due to normal use.
cutting or cuts slowly.
Dust inside the
• This is due to normal use.
motor cover.
The machine is not
• The table is not set into the right angles with
cutting 45° or 90°
regards to the band.
angles.
• The band is dull or there was too much
pressure exercised in the work piece.
The band cannot be
• The flywheels are crooked.
positioned
adequately in the
• The flywheel alignment knob has not been
flywheels.
adequately adjusted.
• The band is defective.
12
ENGLISH
BLACK
BLACK
L1
YELLOW
BLUE
WHITE
L2
WHITE
120 V
connection
Maintenance
BLACK
YELLOW
BLUE
WHITE
220 V
connection

Troubleshooting

Solution
• Check the cord for wear and tear.
• Go to a
Center to repair.
• Turn off the motor and tighten the band tension
knob.
• Open the cabinets and check the band set up.
• Replace saw band.
• Replace band.
• Use the support fence.
• Feed the work piece slowly and with moderate and
constant pressure to prevent the band from bending.
• Replace band with a new one.
Adjust the band guides (see page 8).
• Replace the band (see page 11).
• Install the band correctly.
• Clean the machine regularly. Open the cabinets and
remove dust with a vacuum cleaner and a brush.
• Clean the ventilation slots in the motor with a
vacuum cleaner. Remove dust constantly to prevent it
gets into the cover.
• Adjust the table (see page 7).
• Replace the band or exercise lower pressure on the
work piece.
• Go to a
Center to repair.
• Adjust the knob (see page 11).
• Replace the band with a new one.
BLACK
L1
WHITE
L2
Authorized Service
Authorized Service

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

16277

Tabla de contenido