CONNECTING DRYER POWER
CORD (cont.)
For 3-wire Connection ONLY:
D
Be sure the dryer's green ground wire
is connected to green ground screw on
cabinet rear.
Ground
Wire
(3-Wire Connection Shown)
For 4-wire Connection ONLY:
Remove the dryer's ground wire from
behind the green ground screw and
connect it to the center screw of the
terminal block.
Attach ground wire of power cord to the
cabinet with the green ground screw.
Power
Cord
Ground
Wire
(4-Wire Connection Shown)
Installation Instructions
27
CONNECTING DRYER POWER
CORD (cont.)
For 3-wire and 4-wire Connection:
E
Connect the neutral (center line on 3-wire,
white line on 4-wire) line to the center of
terminal block.
(3-Wire Connection Shown)
For 3-wire and 4-wire Connection: Tighten
F
all terminal block screws completely.
(3-Wire Connection Shown)
For 3-wire and 4-wire Connection:
G
Reinstall the terminal block access cover.
IMPORTANT: Do not leave the access
cover off.