ADJUSTING GAS CONTROL VALVE MINIMUM SETTING (TOP BURNERS)
Important
This adjustment is only
required if the type of
gas to be connected is
different from that used
for testing after the
conversion procedure
has been carried out
(see page 22). Before
making
this
ment, check that the
gas supply pressure is
the same as the rated
pressure for the type of
gas in use (see table at back of manual).
To carry out this ope ration, proceed as fol-
lows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (B) and remove the con-
trol panel (C).
ADJUSTING GAS CONTROL VALVE MINIMUM SETTING (OVEN)
IT
Important
This adjustment is only
GB
required if the type of
gas to be connected is
different
from
DE
used for testing after
the conversion proce-
FR
dure has been carried
out (see page 22). Be-
fore making this ad-
ES
justment, check that
the gas supply pres-
sure is the same as the
rated pressure for the
type of gas in use (see table at back of man-
ual).
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the scr ews (B) and remo ve the control
panel (C).
English
adjust-
that
B
C
A
4 - Remove the injector (D) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - Fully screw the injector.
6 - After making the setting, seal the screw w ith
paint.
7 - Replace the control panel (C) and the knobs (A)
on completion of the operation.
B
C
A
4 - Remove the injector (D) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - Fully screw the injector.
6 - After making the setting, seal the screw w ith
paint.
7 - Replace the control panel (C) and the knobs (A)
on completion of the operation.
- 24 -
D
IDM-39618701200.tif
D
IDM-39603622600.tif