Error
Appliance cannot be started
Insufficient water quantity
Insufficient vacuum perfor-
mance
Insufficient cleaning result
Brushes do not turn
Appliance vibrates.
8
English
Faults
Remedy
Check if the mains plug is connected.
Socket fuse rating too low, look for proper socket.
Check fresh water level, refill tank if necessary.
Clean the ball valve in the solution tank.
Check and ensure that the solution tank is seated properly on the appliance.
Filter in the solution tank is plugged, clean filter.
Check hoses for blockages; clean if required.
Empty the recovery tank.
Check and ensure that the solution tank is seated properly on the wastewater reservoir.
Check seals on the solution tank, clean if necessary.
Clean the seals between the appliance and the recovery tank and check for tightness,
replace if required.
Clean the lint trap.
Clean the squeegee blades on the squeegee tool, replace if required
Suction channel plugged, clean.
Check if the vacuum bar is plugged, remove plug if required
Increase brush contact pressure.
Check the brushes for wear, replace if required.
Use brush rollers suited for the type of dirt and floor covering.
Check if foreign matters block the brushes; remove foreign matter if required.
Reduce contact pressure.
Overcurrent protective switch was triggered. The overcurrent protective switch will al-
low the operation after max. one minute.
Brush rollers are deformed because they were not unloaded by tilting the slider verti-
cally when parking the appliance; replace brush rollers.