Installation instructions
B-1893x | B-1993x
Motor-driven shoot-bolt lock for narrow stile systems
ATTENTION
WARNING
52
4.4
Motor-driven daytime release
(only active if the link has been severed)
To activate the motor-driven daytime release, the link must be severed as shown,
e.g. with diagonal cutter.
In the as-delivered condition, the motor-driven daytime release is not possible!
Disconnect the controller from the power supply before you sever the link!
Once the power supply has been restored, the controller B-54900-01-3-9 reboots.
The permanent release function can then be used.
B-54900-01-3-9
Fig.12: Severing the link
When the link is severed, the approval for use at fire and smoke protection doors is invalidated!
The classification codes then change to:
1
A
0
EN 1125:
3 7 7
1 3 2
B C
2
EN
0
EN 179:
3 7 7
1 3 4
2 AC