Installation instructions
B-1893x | B-1993x
Motor-driven shoot-bolt lock for narrow stile systems
64
Problem
"Locked" signal does not
appear
Signal "Unlocked" position
does not appear
Latch monitoring without
function
Deadbolt monitoring not
functional
(only with B-1893x)
Daytime release cannot be
adjusted
Programming mode cannot be
initiated
EN
Cause
y
y
"Locked by motor" relay
contact is not assigned.
y
y
Lock cannot move to initial
position
y
y
"Unlocked by motor" relay
contact is not assigned.
y
y
Lock cannot move to final
position
y
y
Incorrect cable assignment
y
y
Incorrect cable assignment
y
y
Link not severed
y
y
The signal at the control
input drops out
y
y
Service plug not inserted
y
y
Service plug not removed
between 2 programming
procedures
Help
y
y
Check wiring
Signal input (BK, GY, BNGN)
Signal output (terminal
41 and 51) (see point 1.1)
y
y
Foreign object in the lock
y
y
Check wiring
Signal input (BK, GY, RDBU,
WHGN)
Signal output (terminal
42 and 52) (see point 2.4)
y
y
Foreign object in the lock
y
y
Check wiring
Signal input (RD)
Signal output (terminal
44 and 54) (see point 2.4)
y
y
Check wiring
Signal input (VT)
Signal output (terminal
43 and 53) (see point 2.4)
y
y
Sever link (see point 4.4)
y
y
Make sure that the control-
ler is receiving a continuous
signal
y
y
Insert the service plug into
the controller (see point 6)
y
y
The service plug must be
removed in order to exit
programming mode. You
can only start another
programming operation
once you have done this
(see point 6)
10.2017 | 20734ES | Designed in Germany