30" minimum from bottom of
overhead Hood to cooking
surface (40" min. if hood
contains combustible
18"
materials
)
Min.
*35-7/8" Min. Range Height
with Leveling Legs fully
retracted
*36-3/4" Max. Range Height
with Leveling Legs fully
extended.
30" or 36" Wide Hood
For 30" Ranges
}
36" or 42" for Island
36" or 42" Wide Hood
For 36" Ranges
}
42" or 48" for Island
Min. Distance Between Overhead Cabinets
of Combustible Material
30" Range – 30"
36" Range – 36"
Range width
30" or 36"
Cooking
Surface
For Electrical and Gas Supply Zone, see
Figure 3A.
as defined in the "National Fuel Gas Code" (ANSI Z223.1,
Current Edition). *The range height is adjustable. The level
of the range top must be at the same level or above the
countertop level.
13" Max.
}
Cabinet
Depth
10" Min. to
combustible
side wall
material
,
(both sides)
Figure 1: Cabinet Clearances
CAUTION:
See Figure 2
40" Min. to
combustible
,
material
Ð
from cooking
surface