Periodical Maintenance - SEA MARK TANK E 270 Manual De Instalación

Tabla de contenido

Publicidad

Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
MANUAL RELEASE SYSTEM
WARNING: Always switch off the main power (110V or 230V) before servicing the operator.
WARNING: SEA recommends to the end user to release the operator only after having switched off the electric power.
Always contact a professional installer in case of not correct working of the operator.

PERIODICAL MAINTENANCE

1) Check the solidity and the stability of the gate, especially the points of support and/or rotation
of the gate (pivots).
2) Check the oil level of the hydraulic/in oil bath operators (cap on rear cover)
3) Change the hydraulic oil with the one recommended from the head company
4) Check the release function
5) Check the by-pass valves function
6) Check and lubricate the fixing pins
7) Check the integrity of the connection cables
8) Check the function and the positive stops condition in opening and closing (where there is
present a mechanical positive stop accessory)
9) Check the good status of all parts which are forced (rear bracket, oscillating bracket and front
bracket).
10) Check the operating of all accessories, especially the function of all safety devices and of the
Safety Gate.
11) After having executed the periodical maintenance operations it is necessary to repeat
the test and the putting in service of the automation
12) Lubricate the shaft (see page 3) with SEA grease (GREASE GL 00 Cod.65000009)
All the above described operations MUST be made exclusively by an authorized installer.
67410019
®
To the attention of users and technicians
Up
Down
REV 00 - 07/2013
MARK TANK E
English
English
UNLOCK
LOCK
Fig. 25
Annual
Annual
4 years
Annual
Annual
Annual
Annual
Annual
Annual
Annual
Annual
Annual
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mark tank e 390

Tabla de contenido