Adjustments
Disconnect plug from power source
before
performing
any assembly,
adjustment or repair to avoid possible injury.
NOTE:
Your slide compound
miter saw was com-
pletely adjusted at the factory.
However, during ship-
ment, slight misalignment may have occurred.
Check
the following settings and adjust if necessary prior to
using this compound
miter saw.
.
2.
.
4.
Blade Square (90 °)
To Table
90 ° Blade Alignment
Check
Rotate table to 0° position and lock in place.
Make sure head assembly is pushed back fully
against stop and slide rail lock knob is tightened.
Lower head assembly. Lock in place.
Use a combination
square to check blade square-
ness to table.
Place the combination
square on
the table and press it against the blade. If the
blade does
not contact
the full length of the
square, (Figure 6) follow the alignment procedure.
0 ° Stop
Screw
Jam
Nut
Figure 7. Bevel 0 ° Stop Screw and Jam Nut
7. Adjust
bevel indicator.
Loosen
screw and
align indicator to the 0° mark. Tighten screw
(Figure 8).
Combination
Square
Blade
Figure 6. Blade Square to Table
90 ° Blade Alignment
Adjustment
1. Loosen bevel lock handle.
2. Move the head off of the 0° stop.
3. Lower 0° stop screw and jam nut with 12mm
or adjustable wrench.
4. Move the saw back to 0° stop.
5. Push square against blade (fig. 6).
6. Adjust 0° bevel stop screw with 12mm or
adjustable
wrench
until the blade makes
contact
with the full length of the square.
Tighten jam nut (Figure 7).
Figure 8. Bevel Indicator
Adjust
to 0°
Bevel
Indicator
Screw