Apéndice A: parámetros
Núme
Descripción del parámetro
ro del
pará
metro
16-27
Potencia filtrada [CV]
16-3* Estado Drive
16-30
Tensión Bus CC
16-32
Energía freno / s
16-33
Energía freno / 2 min
16-34
Temp. disipador
16-35
Témico inversor
16-36
Int. Nom. Inv.
16-37
Máx. Int. Inv.
16-38
Estado ctrlador SL
16-39
Temp. tarjeta control
16-40
Buffer de registro lleno.
16-41
Buffer de registro lleno
16-43
Estado de acciones temporizadas
16-49
Origen del fallo de intensidad
16-5* Ref. & realim.
16-50
Referencia externa
16-52
Realimentación [Unit]
16-53
Referencia Digi pot
16-54
Realim. 1 [Unidad]
16-55
Realim. 2 [Unidad]
16-56
Realim. 3 [Unidad]
16-58
Salida PID [%]
16-6* Entradas y salidas
16-60
Entrada digital
16-61
Terminal 53 ajuste conex.
16-62
Entrada analógica 53
16-63
Terminal 54 ajuste conex.
16-64
Entrada analógica 54
16-65
Salida analógica 42 [mA]
16-66
Salida digital [bin]
16-67
Ent. pulsos #29 [Hz]
16-68
Ent. pulsos #33 [Hz]
16-69
Salida pulsos #27 [Hz]
16-70
Salida pulsos #29 [Hz]
16-71
Salida Relé [bin]
16-72
Contador A
16-73
Contador B
16-75
Entr. analóg. X30/11
16-76
Entr. analóg. X30/12
16-77
Salida analógica X30/8 [mA]
16-78
Salida analógica X45/1 [mA]
16-79
Salida analógica X45/3 [mA]
16-8* Fieldb. y puerto FC
16-80
Fieldbus CTW 1
16-82
Fieldbus REF 1
16-84
Opción comun. STW
16-85
Puerto FC CTW 1
16-86
Puerto FC REF 1
MG16I305
Manual de funcionamiento
Valor predeter-
4-set-up (4
minado
ajustes)
0 hp
All set-ups
0 V
All set-ups
0 kW
All set-ups
0 kW
All set-ups
0 °C
All set-ups
0 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 N/A
All set-ups
0 °C
All set-ups
[0] No
All set-ups
0 N/A
All set-ups
[0] Acc. temp.
autom.
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 ProcessCtrlUnit
All set-ups
0 N/A
All set-ups
0 ProcessCtrlUnit
All set-ups
0 ProcessCtrlUnit
All set-ups
0 ProcessCtrlUnit
All set-ups
0 %
All set-ups
0 N/A
All set-ups
[0] Intensidad
All set-ups
0 N/A
All set-ups
[0] Intensidad
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Danfoss A/S © 12/2015 Reservados todos los derechos.
Cambio durante
Índice de
funcionamiento
conversión
FALSE
-3
FALSE
0
FALSE
0
FALSE
0
FALSE
100
FALSE
0
FALSE
-2
FALSE
-2
FALSE
0
FALSE
100
TRUE
-
TRUE
0
TRUE
-
TRUE
0
FALSE
-1
FALSE
-3
FALSE
-2
FALSE
-3
FALSE
-3
FALSE
-3
TRUE
-1
FALSE
0
FALSE
-
FALSE
-3
FALSE
-
FALSE
-3
FALSE
-3
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
TRUE
0
TRUE
0
FALSE
-3
FALSE
-3
FALSE
-3
FALSE
-3
FALSE
-3
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
Tipo
Int32
Uint16
Uint32
Uint32
Uint8
Uint8
Uint32
Uint32
Uint8
Uint8
Uint8
VisStr[50]
Uint8
Uint8
Int16
Int32
9
9
Int16
Int32
Int32
Int32
Int16
Uint16
Uint8
Int32
Uint8
Int32
Int16
Int16
Int32
Int32
Int32
Int32
Int16
Int32
Int32
Int32
Int32
Int16
Int16
Int16
V2
N2
V2
V2
N2
121