SPX Aqua Jet UNO Manual De Instrucciones página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
Caution
Do not use the pump unit for any other li-
quids then fresh-water and seawater.
Do not overpressure tank. Pressure over 12
bar (170 psi) may rupture tank and cause
personal injury.
Temperature
Max liquid temperature: +50°C/+120°F
Max ambient temperature: +60°C/+140°F
Winterizing
If water is not drained from the system during
freezing temperatures, damage is likely to be
sustained in the plumbing and in the pump.
To prevent damage follow the instructions
beneath:
1. Drain water storage tank.
2. Open all taps.
3. Run pump until remaining water is
expelled.
4. Disconnect inlet and outlet tubes
5. Run pump briefly to confirm that water
has been expelled.
6. Taps shall remain open and pump fittings
shall remain disconnected until tempera-
tures are above freezing.
Never start a frozen pump. Even if it is drai-
ned it might contain a small amount of frozen
water that locks the rotor.
Service instructions
(see page
)
37-43
Change of Switch (pos A) WPS
2.9/3.5
1. Remove the cables from the power
source.
2. Remove the screws (27) and then
remove the complete switch including
diaphragm (18).
3. Cut the connection to the motor (red).
4. Locate the new diaphragm (18) and
then the new complete switch.
5. Take the new switch and attach the
cables to motor and power source.
Use the attached jointing sleeve to
connect the motor cable.
Change of Switch (pos A) WPS 5.2
1. Remove the cables from the power
source.
2. Remove the screws (28) and then
remove the complete switch including
diaphragm (19).
3. Cut the connection to the motor (red).
4. Locate the new diaphragm (19) and
then the new complete switch.
5. Take the new switch and attach the
cables to motor and power source.
Use the attached jointing sleeve to
connect the motor cable.
> English
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aqua jet uno max

Tabla de contenido