Lenze E94ASHE Serie Instrucciones Para El Montaje página 44

Ocultar thumbs Ver también para E94ASHE Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Overview
Standard device 
Pos.
Description
MXI1
Module slot for extension 1, e.g. communication
MXI2
Module slot for extension 2, e.g. communication
MMI
Module slot for memory modules
MSI
Module slot for safety modules
X1
System bus (CAN), under the cover
X2
24-V supply and state bus
X3
Analog inputs and analog outputs
X4
Digital outputs
X5
Digital inputs
X6
Diagnostics
X7
Resolver
X8
Encoder
Lower cap
Nameplate, retractable
Upper cap
EMC clamp
Warning sticker - place close to the device in a clearly visible manner!
The LED display enables fast indication of several operating states.
LED
Labelling
CAN-RUN
CAN-ERR
DRIVE READY
DRIVE ERROR
24 V
USER
SSP94LED01
Pos.
Symbol
Installation backplane 
Pos.
Description
X100
Mains / DC-bus voltage
X105
Motor / external brake resistor
X106
Motor temperature monitoring
X107
Control of motor holding brake
X109
DC busbar +
X110
DC busbar -
EMC wire clamp (for device sizes II + III), replaces 1x 
EMC shield clamp
© 2006 Lenze Drive Systems GmbH, Hans-Lenze-Straße 1, D-31855 Aerzen
No part of this documentation may be reproduced or made accessible to third parties without written consent by Lenze Drive
Systems GmbH.
All information given in this documentation has been selected carefully and complies with the hardware and software described.
Nevertheless, deviations cannot be ruled out. We do not take any responsibility or liability for damages which might possibly occur.
Necessary corrections will be included in subsequent editions.
44
Colour
Description
green
CAN bus o.k.
red
CAN bus error
green
Standard device is ready for operation
red
Error in the standard device or due to the application
green
24-V supply voltage o.k.
yellow
Message parameterised by the application
Description
Long discharge time: All power terminals carry hazardous voltages for at
least 3 minutes after mains disconnection!
High discharge current: Fixed installation and PE connection to EN 61800-5-1
required!
Electrostatic sensitive devices: Before working on the device, personnel must
ensure that they are free of electrostatic charge!
Design
HighLine
2/2
4
8
1
Inoperable when "StateLine" design is
used
Design
HighLine
Optional
Optional
(for DC-bus connection)
3 or 2
EDK94ASH24 DE/EN/FR/ES/IT 3.1
StateLine
1/0
1
4
1
StateLine
1

Publicidad

Tabla de contenido
loading

Tabla de contenido