Displays
Pos.
MS
EN
ME
PS
DE
EDK94ASH24 DE/EN/FR/ES/IT 3.1
Colour
State
On
Blinking
Green
Off
On
Yellow
Off
On
Blinking
Red
Flashing
Off
On
Red
Blinking
Off
Red
On
Wiring the device modules
Safety modules
Description
Drive-based safety is initialised faultlessly.
Drive-based safety is initialised faultlessly. Internal
communication to the standard device is not possible.
Drive-based safety is not initialised.
Acknowledgement is not possible.
Controller enabled
Non-safe display "STO"
System error:
After a serious internal error, STO is activated.
Can only be reset by switching the 24V supply.
Error:
After an internal error or an error at the safe inputs, a
standstill function is activated.
The safety class is quit.
Acknowledgement is possible.
Fault:
A monitoring function has responded and activated a
standstill function.
The safety class is not quit.
Acknowledgement is possible.
Error-free operation
Error PROFIsafe:
Communication is not possible.
Acknowledgement is possible.
No valid PROFIsafe configuration
PROFIsafe is error-free.
The module is not accepted by the standard device (see notes
given in the documentation for the standard device).
8
81