Terminal Assignment - Lenze E94ASHE Serie Instrucciones Para El Montaje

Ocultar thumbs Ver también para E94ASHE Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Connections
Pos.
Description
PROFIsafe target address switch (on the left housing side)
X82.1
X82.2
Pluggable terminal strips for input and output signals
X82.3
X82.4
Addressing
An unambiguous PROFIsafe target address ensures that a data telegram reaches the
correct node.
The valid address within the range between 1 and 1023 can be set via the DIP switch . The
address 0 is invalid and causes an error in the module.
DIP switch 
Value of the address bit
Note!
The combination "safety module SM300 from version VA 1.08 and
communication module PROFIBUS from version VB 0.93" offers the
opportunity to avoid the error that occurs when an address is set to 0. For this
purpose, a defined PROFIsafe target address must be saved in
C13897 or 14897 in the PROFIBUS communication module.

Terminal assignment

X82.1
X82.2
EDK94ASH24 DE/EN/FR/ES/IT 3.1
1
2
1
2
Labelling
Description
n. c.
n. c.
n. c.
n. c.
n. c.
This terminal strip is not assigned.
n. c.
n. c.
n. c.
n. c.
Labelling
Description
-
GND external supply
+
24 V external supply via a safely separated power supply unit (SELV/PELV)
n. c.
n. c.
This part of the terminal strip is not assigned.
n. c.
n. c.
AIE
Error confirmation input (Acknowledge Input Error)
CLA
Clock output for passive sensors, channel A (clock A)
CLB
Clock output for passive sensors, channel B (clock B)
Wiring the device modules
Safety modules
Labelling
3
4
5
6
4
8
16
32
8
7
8
9
0
64
128
256
512
79

Publicidad

Tabla de contenido
loading

Tabla de contenido