Ideal TightSight 61-763 Manual De Instrucciones página 6

Ocultar thumbs Ver también para TightSight 61-763:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Auto Power Off (APO) Feature Disable
The meter automatically powers itself down after about 30 minutes of no use. Press any
button, and the meter will wake up and display the last reading taken before power down.
To Disable APO, press and hold the (
/ Hz) button while turning the dial to any desired function.
When APO is defeated, the "APO" will be removed from the display. Turning the meter off and back
on will restore the APO default.
Backlight
Press the
button in the middle of the meter to turn the back-
light on and off. The green backlight will remain lit for about
3 minutes before it automatically turns off to conserve
Backlight on in
battery power.
all functions.
Note: Backlight consumes 4x the battery power .
Measuring AC Current (Amps):
H
N
CORRECT
INCORRECT
CORRECT
Single
Currents
Use with
Conductor
cancel
line splitter
only
Note: 61-765 model also measures DC Current.
6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tightsight 61-765Tightsight 61-773Tightsight 61-775

Tabla de contenido