► In the gravity fed system, the ideal flow rate per DN 110 supply line is between 6000 l/h and 8500 l/h.
Provide sufficient supply lines.
4.2.2

Connecting the inlet

Pump fed system
The filter system is equipped with a 50 mm (2 ") or 38 mm (1.5 ") connection for the filter pump.
► You can additionally connect a UVC clarifier. (→ Fitting the UVC clarifier)
► The maximum flow rate is 12500 l/h.
► It is necessary to remove a screen element to access the internal connection. (→ Removing/fitting a
screen element)
► Leave the connection for the filter pump on the container closed if it is to remain unused.
How to proceed:
 A, G
1. Unscrew the cover cap and remove the non-return valve and flat seal.
2. Screw the union nut with 50 mm (2 ") or 38 mm (1.5 ") hose connector and flat seal or non-return valve
onto the connection. Hand-tighten the union nut.
– Use the flat seal if continuous operation of the pump is planned, the non-return valve for interval
operation.
3. Slip the 50 mm (2") hose of the filter pump onto the hose connector and secure with a hose clip.
4. Screw the union nut with the 90° connection bend (2 ") and the seal onto the connection on the inside
of the container. Hand-tighten the union nut.
– Ensure that the connection bend points downwards.
– A correctly positioned connection bend prevents unintended overflow (emptying of the pond) and
also serves to reduce noise emissions.
Gravity fed system
 B, I
The ProfiClear Premium Compact module has two DN 110 connections.
► Recommendation: Limit the flow rate to 8500 l/h per DN 110 inlet.
► Use suitable DN 110 pipes for connecting the bottom outlet and/or skimmer and the inlet.
► Secure the pipes so that fish cannot swim into them.
4.2.3

Fitting the UVC clarifier

Pump fed system
The Bitron UVC clarifier is fitted to the drum filter module. The max. flow rate of the Bitron and the overall
system is 12500 l/h.
► It is necessary to remove a screen element to access the sealing plugs. (→ Removing/fitting a screen
element)
► When two filter pumps are operated, one filter pump is connected to a ∅ 50 mm (2") inlet, the other to
the Bitron. (→ Connecting the inlet)
N O T E
If two filter pumps are to be connected, they must always be operated simultaneously or be equipped
with a non-return valve.