Installation And Connection; Installing The Filter Module And Connecting It To The Upstream Filter Module; Connecting The Dirt Outlet; Connecting The Aerator - Oase ProfiClear Premium XL Puesta En Marcha

Ocultar thumbs Ver también para ProfiClear Premium XL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27

Installation and connection

Installing the filter module and connecting it to the upstream filter module

How to proceed:
 C
1. Push the transition sleeve onto the inlet and fasten the transition sleeve with the hose clip.
– For later installation work: Turn the hose clip so that the hose clip screw is accessible from
the side.
2. Push the filter module up to the previous filter module so that its outlet is positioned in the
transition sleeve of the filter module up to the stop.
– Ensure that the dirt water outlets of all filter modules are positioned on the same side.
3. Fasten the transition sleeve on the outlet of the upstream filter module using the hose clip.
– For later installation work: Turn the hose clip so that the hose clip screw is accessible from
the side.

Connecting the dirt outlet

 A
The water in the container can be drained via the DN 75 dirt outlet with a slide valve at the bot-
tom of the container if required (for cleaning, repair, overwintering).
• Connect a suitable DN 75 pipe and drain the dirty water into the sewer system.
Connect the pipe DN 75 and the pipe DN 110 from the filter drum for coarse dirt to a joint
pipe DN 110 and drain the dirty water into the sewer system. This makes it more convenient
to flush out the pipe with sufficient pressure.

Connecting the aerator

Use of aerators promotes water circulation in the container and is ideal for ensuring even bacte-
rial colonisation of the ClearWaves.
• Recommended aerator: AquaOxy 2500
How to proceed:
 D
• Connect the air hose from the aerator with the air connection and attach the air connection
to the recess on the container.
– For an air hose ∅ 4 mm use the 4/9 mm adapter.
– Fasten the air hose to the connections with cable ties, if necessary.
EN
15

Publicidad

Tabla de contenido
loading

Tabla de contenido