ALARM WILL NOT SOUND
Avoid contact with the crib when the monitor is ON.
•
•
Place crib near a solid supporting wall to avoid Sensor Pad from detecting movement from outside the crib.
Turn OFF crib mobile, fans, loud music or anything else that may cause vibration.
•
You may need to decrease the sensitivity (refer to Step 4.3).
•
SENSOR PAD LIGHT INDICATOR FLASHING RED
•
Make sure there is no bedding between the mattress and the Sensor Pad.
•
The Sensor Pad must rest on a completely flat and firm surface. If the crib has a spring or slat base, place a hard board between
the crib base and the Sensor Pad measuring at least 13'' x 13'' (33 x 33 cm) and 1/4'' (6 mm) thick.
•
Make sure Sensor Pad is positioned as described under the setup requirements. Sensitivity may need to be adjusted
(refer to Step 4.3).
LOSS OF CONNECTIVITY (NURSERY UNIT BLUE LIGHT FLASHES AND EMITS A SOUND EVERY 20 SECONDS)
•
Bring the units closer together.
Press and hold for 2 seconds the Nursery Unit Pairing button, the Nursery Unit will emit a sound and will flash blue to confirm
•
connectivity.
NO POWER
•
Check or replace batteries.
Make sure monitor is ON.
•
LIMITED WARRANTY
Angelcare
warrants to the original owner of this product that Angelcare
®
monitor is free from any material and workmanship defects for the term of
the warranty period (see warranty table below to determine the warranty
for your country). If this monitoring system fails to function properly when
used as directed under normal conditions and during the warranty period,
Angelcare
will either repair or replace the product, at our discretion, free
®
of charge. Please contact your local distributor to validate warranty and
warranty period.
The product must be accompanied by a proof of purchase, either a bill of
sale or other proof that the monitoring system is within the warranty period.
Angelcare
will bear the cost of repairing or replacing the product and
®
shipping it back to you.
This warranty does not apply to a product which has been
damaged as a result of improper maintenance, an accident,
improper voltage supply or any other form of misuse. The warranty
is also void if the owner repairs or modifies the product in any
way. Angelcare
is not liable for any incidental or consequential
®
damages with regard to this product. The warranty also excludes
any liability other than what is stated above. No other warranty
is given.
TECHNICAL SPECIFICATIONS
Range:
Open field (Open area without obstructions): up to 8 meters.
Power Supply:
2 AAA alkaline batteries for Nursery Unit (not included)
1 CR3032 3V battery for wireless Sensor Pad (included)
Caution: To reduce the risk of electric shock, do not expose this product
to rain or moisture.
Danger of explosion if batteries are incorrectly replaced. The battery for
the Sensor Pad is a user replaceable Lithium (not Li-Ion) battery and is NOT
rechargeable. Only use the Angelcare
To obtain information on replacement batteries please contact Angelcare
customer service: www.angelcarebaby.com or contact your local
distributor. Instructions will be included with the replacement battery.
Keep all batteries away from children.
8
®
recommended replacement battery.
®
This warranty does not cover products and accessories which are not
Angelcare-branded, or any problems that result from usage that is not
in accordance with product instructions, failure to follow the product
instructions, or problems caused by using accessories, parts
or components not supplied by Angelcare.
LEGAL RIGHTS VARY FROM COUNTRY TO COUNTRY. SOME COUNTRIES DO NOT
ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.
WE ARE NOT IN ANY WAY RESPONSIBLE FOR ANY OUTCOME RESULTING FROM
THE USE OF THIS PRODUCT.
IMPORTANT! This Angelcare
do not return this product to the store. If you have questions or need help,
please call your distributor before returning this product.
WARRANTY TERM PER COUNTRY
North America
Batteries:
• DO NOT mix old and new batteries.
• DO NOT mix alkaline standard (carbon-zinc), or rechargeable
(NI-CD, NIMH, etc.) batteries.
• CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT
TYPE.
Transmission:
Data transmission between the Nursery Unit and the sensor Pad is made on
2.402 to 2.480 GHz frequency for North America.
Maximum RF Power Transmitted: 4dBm (2.5mW)
®
RF Channel no. : 79
PROTECT THE ENVIRONMENT
The wheelie bin symbols mean that according to local laws and
regulations your product and/or its battery shall be disposed of
separately from household waste. When the product/battery reaches
its end of life take it to a collection point designated by local authorities.
The seperate disposal and recycling will help conserve natural resources
and protect human health and the environment. Refer to User's Guide for
removal of batteries.
monitor is a personal care product. Please
®