6 - Guarantee

The Selwatch model is guaranteed for two years
(electronic parts, peristaltic pump and cell), ex-
cluding spare parts.
This guarantee covers every error noticed during
this period that is not due to improper use by
the user. Only the manufacturer is competent to
judge how the complaint should be handled.
We cannot be held responsible for the cost of
maintaining the water in a fit state for bathing
while the machine is being repaired (use of che-
mical products, etc.).
The user should accept a check of their installa-
tion by our after-sales service, if necessary; they
will undertake all required tests to detect any
fault that has been brought to our attention.
The guarantee will take effect from the
installation date (upon presentation of the
invoice), or otherwise by the serial number
printed on the box.
As far as the user is concerned, this guarantee
presents no obstacle to the application of the
legal guarantee against defects as covered by
articles 1641 and following of the Civil Code.
Neither does it exonerate from the legal confor-
mity guarantee integrated into the consumer
code by decree 2005136 of 17/02/05.
Display
Type of error
Errors or faults relating to pH and chlorine
Normal
NOr
A01
Photometer
sensor
problem
Sensor
A02
problem
A03
Sensor
problem
A08
no flow
25
You have the following
problem:
Correct operation
the photometer sensor's
connections are defective
the sample is too dark
the case is open
or half-open
there is no flow
in the circuit

7 - Troubleshooting

Please contact your retailer directly if you
have any problems.
Pacific Service
(for professional customers only):
France 05 53 35 69 06
7.

- Good to know

1
After having produced the required amount of
chlorine, the device commences a countdown of
ten minutes. This is the amount of time neces-
sary for the chlorine to be mixed properly with the
water in the swimming pool (homogenisation).
You will also come across a countdown of 90 mi-
nutes. This corresponds to the time between two
analyses (this time will not always be the same,
since it will depend on the calculation made by
the microprocessor).
7.
- Liste des anomalies
2
Your device shows an error code.
Please use the following table to identify the
error and resolve it.
Here is how to resolve it.
check the connections
there are too many impurities in the
water / There is too much reagent
in the analysis chamber
close the case to protect the
device from the light
check the flow detector
Intervention by
a technician
yes
yes
yes
yes / no