3.

- Switching on the device

2
Switch on the device, after first having followed
the guidelines for first use and switching-on of
the electrolyser or meter pump.
Press the ON/OFF button at the bottom of
the right-hand side of the Selwatch box. A few
seconds after switching-on, the device will
display a three-minute countdown to the start of
a time-out.
You should undertake the following
operations during the countdown:
Add the reagent in semi-automatic mode
Note: semi-automatic mode is used for starting
the reagent pump during installation of the
device (recommended configuration).
Press
for 3 seconds.
The device displays ASA.The reagent pump
will continue to work until the reagent is detected,
when the diodes on the dial will start flashing
one after the other (this may take between five
and ten minutes).
Or start the reagent pump manually
Note: manual mode is advised
when restarting the device, since it is faster.
Quickly press
.
The device will display AMO.
The
chlorine alarm lights up. Keep pressing
Cl
the button
until the reagent pump starts
(the diodes on the dial start flashing one after
the other).
Add the correctors
Quickly press
. The device will display AMO.
Choose the corrector that you wish to add.
- for the chlorine corrector: press
chlorine corrector production indicator will light up.
- for the pH- corrector: press
corrector production indicator will light up.
pH
- for the pH+ corrector: press
pH+
+
corrector production indicator will
pH
light up.
Keep
pressed to validate.
The first analysis will take place two to three
minutes later.
C
twice. The
Cl
C
twice. The pH-
pH
C
twice. The
pH

4 - Specificities of the menus

4.

- Chlorine menu

1
Below you will find a description of the but-
tons that you will find useful when adjusting
settings and browsing the Chlorine menu.
Chlorine menu
press... to enter
the Chlorine menu
press ... to navigate
the menu
press... to enter
a setting and change it
press ... for three
seconds to validate and
exit the Chlorine menu
You may change the following
settings during the countdown :
Distant Filtration menu - display : F
By default, the device is set to a distant filtration
of less than 20 metres and displays OFF. Switch
to display ON to change to a distant filtration of
more than 20 metres.
Public Pool Mode menu - display : PRO
By default, the device is set to OFF (this
corresponds to analyses of 20 to 30 min.).
Switch to display ON to change to Detailed
Analyses Mode (this corresponds to the
systematic analyses every 10 to 30 min for
public swimming pools).
Production Method Menu - display : CL
(only the model Selwatch
T
3-03, 3-04
3-05)
ypes
and
By default, the device is set to "electrolyser" and
displays ECL. If you have a chlorine meter pump,
switch to PCLdisplay, then validate by pressing
C
for three seconds.
Cl
+
C
then
Cl
+
C
then
to switch
Cl
from one setting
to another
+
C
then
or
to
Cl
change the value
C
Cl
20