LSI
Specifications
Safety outputs
(OSSD A, OSSD B),
dynamic, High-active
Quantity
Switching voltage High-active
(Ueff)
Voltage for LOW
Switching current (referred to
EXT_GND)
Short-circuit protected
In case of error: Leakage current,
break in GND cable. The
downstream control element
must recognise this status as
Low.
Pure load capacity
Pure load inductance
Switching sequence (without
switchover and without
simultaneous monitoring)
Response time at double speed
Cable length
Cable cross-section
Permissible line impedance
Test pulse data (OSSD_Test)
Test pulse width
Test frequency
Test pulse data (Test_Ub)
Test pulse width
Test frequency
Safety category
DIN V 19250
EN 954-1
IEC/EN 61496-1
8 008 308/M848/06-05-02 Operating Instructions · LSI
© SICK AG · Industrial Safety Systems · Germany · All rights reserved
Data
min.
typ.
Two 2-channel outputs
Uv -3,4 V
0 V
2 mA
by monitoring of outputs
100 us
Once per scan
100 us
Twice per scan
Single error fail-safe
Requirement class 4
Category 3
Type 3
GB
max.
Uv
2.5 V
250 mA
1,1 mA
100 nF
2 H
1
6
/
s
190 ms
50 m
2.5 mm
2
2.5 Ohm
157