8. SPECIFICATIONS
Tracing mode (de-energized)
Locating mode
Sensitivity (typical)
Display backlight
Audio indication
Compatible transmitter
Display
Update rate
Operating temperature and
humidity
Storage temperature and
humidity
Operating altitude
Pollution degree
IP-rating
Drop proof
Power supply
Auto power off
Battery life
Low battery indication
Agency approval
Safety compliance
Electromagnetic Compatibility
Size (H x W x L)
Weight
8 kHz (8,192 Hz)
Ground fault locating
Cable locate mode at 1 meter depth: 10 uA
Fault locate mode: up to 2 MΩ fault
Automatic
Speaker indicates left/right by pulsed/continuous tone
UAT-600-TE Transmitter
33 mm (1.28 in) 128 x 128 BW outdoor LC-Display with auto backlight
Instantaneous
-20 °C to 50 °C (-4 °F to 122 °F), ≤90% RH
-40 °C to 60 °C (-40 °F to 140 °F), ≤90% RH
< 2000 m (< 6561 ft)
2
IP54
1 m (3.28 ft)
Six (6) 1.5 V AA alkaline batteries
15 minutes idle
Will auto turn off after 15 mins if no button pressing
Approx. 60 hours at 21 °C (70 °F) (Typical)
Blinking
®
IEC 61010-1
CSA/UL 61010-1
IEC 61326-1
Korea (KCC): Class A Equipment (Industrial Broadcasting &
Communication Equipment)
[1]
This product meets requirements for industrial (Class A) electromagnetic
wave equipment and the seller or user should take notice of it. This
equipment is intended for use in business environments and is not to be
used in homes.
Approx. 355 x 230 x 120 mm (14 x 9 x 4.7 in)
Approx. 1.9 kg (4.2 lb) (batteries installed)
10