• Use caution when working with voltages above 30 V AC RMS, 42 V AC peak, or 60 V DC. These voltages
pose a shock hazard.
• Do not attempt to connect to any circuit carrying voltage.
• To avoid false readings that can lead to electrical shock and/or injury, replace the batteries as soon as the
low battery indicator appears. Check Product operation on a known source before and after use.
• Use only 6 x AA batteries properly installed in the battery compartment, to power the Product
(see Section 8: BATTERY REPLACEMENT).
• When servicing, use only specified user serviceable replacement parts.
• Adhere to local and national safety codes. Individual protective equipment must be used to prevent shock
and arc blast injury where hazardous live conductors are exposed.
• For use by competent persons only.
• Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures
above 60 °C (140 °F). If the batteries are not removed, battery leakage can damage the Product.
• Follow all battery care from the battery manufacturer.
2. INTRODUCTION
The AF-600-EUR A-Frame cable ground fault finder
is an optional accessory specifically designed for the
Beha-Amprobe UAT-600-EUR series. In combination
with the Transmitter, it will pinpoint the place where
a cable metal conductor (either a sheath or a metallic
conductor of the wire) touches the ground. It can
also detect other conductors to ground faults such as
pipeline coating defects.
3. UNPACKING AND INSPECTION
Your shipping carton should include:
1
A-Frame AF-600
1
Carrying case
1
User manual
If any of the items are damaged or missing, return the complete package to the place of purchase for an exchange.
4. OPERATION
1
29
L
H
2
1
On/off
: Press for 2 seconds to turn on or
turn off the A-Frame.
2
Speaker Volume
between mute and three levels of volume.
3
: Press repeatedly to loop