CHECK LIST
To be integrated with a complete reading of the technical specifications
Positioning and installation
• Room ventilation
• Only the thermal stove outlet passes through the smoke channel/chimney flue
• The smoke channel has: a maximum of 2 curves – a maximum of 2 horizontal metres, at least 1.5 vertical metres
• The exhaust pipes are made of suitable material (recommended: stainless steel)
• When using any flammable materials (e.g. wood), all precautions have been taken to prevent a fire hazard
• The heating capacity has been appropriately assessed considering radiator efficiency: how many kW have been estimated to be
necessary???
• The hydraulic system has been declared to be compliant with the Ministerial Decree 37 ex Law No. 46/90 by a qualified technician.
Use
• Good quality, dry wood pellets are used (diameter 6 mm).
• The chimney pot and ash compartment are clean and well positioned.
• The cleaning rods are moved every day.
• The exchanger tubes and internal parts of the hearth are clean.
• The smoke duct (see page 35) is clean.
• The bleeding process has been applied to the hydraulic system.
• The pressure (read on manometer) is approx. 1-1.5 bar.
REMEMBER TO VACUUM THE COMBUSTION CHAMBER BEFORE EACH IGNITION
Should ignition fail, DO NOT re-ignite until you have emptied the combustion chamber.
39