Weekly Cleaning - EdilKamin MIMI’ Instalación Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
MAINTENANCE
egular maintenance is required for the thermal stove to function correctly.
The thermal stove will trigger the message: '°C smoke/high' or 'MAINTENANCE??' to appear on the panel when
further
cleaning is necessary.
This is preceded by 'Clean exchanger' appearing on the display.
FAILURE TO PERFORM at least SEASONAL MAINTENANCE can cause the thermal stove to malfunction and
any problems deriving from this will not be covered by the warranty.
Non-compliance with maintenance procedures will render the warranty null and void.
Before performing any maintenance, disconnect the appliance from the mains.
Daily cleaning
Cleaning must be carried out with a vacuum cleaner (see optional extras page 35).
The whole procedure takes up a few minutes every day.
Shake the cleaning rods often (when cold) – these are found in the front upper part (*).
*
*
Operations to be carried out when the thermal stove is cold
• Vacuum the door and the hearth.
• Remove the combustion chamber or use the spatula to scrape it and clean out any blocked holes on all sides.
• Vacuum the combustion chamber and clean the contact edges.
• Clean the glass, if necessary (when cold).
Never vacuum hot ashes as this will damage the vacuum cleaner.

Weekly cleaning

• Pulizia del focolare (con scovolo) dopo aver tolto i 2 deviatori fumo (seguire sequenza figure A – B – C).
• svuotare il serbatoio pellet e aspirarne il fondo dopo un periodo di inattività della termostufa e comunque ogni mese.
fig. A
fig. B
fig. C
34