POSSIBLE TROUBLESHOOTING
Warnings are shown until you intervene and press the 0/1 key on the control panel.
It is recommended not to use the thermal stove before verifying that the problem has been resolved.
Should it block, re-ignite the stove after allowing it to shutdown (10 minutes with an audible signal), then press
the 0/1 key.
Never unplug the device during the shutdown process.
It is important for the DEALER to know what warning signal appears on the panel.
TROUBLESHOOTING ADVICE
Pellets do NOT fall into the combustion chamber for the following reasons:
• The feed screw is empty:
fill the feed screw by pressing the + and – keys simultaneously.
• The pellets are blocked in the hopper:
use a vacuum cleaner to empty the pellet hopper.
• The gear motor is broken.
• The feed screw safety thermostat 'disconnects' the electrical supply of the gear motor:
check that it has not overheated. Use a tester or a temporary bridge to verify.
• The water overheating safety thermostat 'disconnects' the electrical supply of the gear motor:
check that the thermal stove contains water. Press the button behind the thermal stove to reset it.
In these cases, you MUST contact the DEALER before re-igniting.
PROBLEM
synoptic panel is off
remote control not working
Water is not hot enough
The chimney pots and smoke ducts connected to the solid fuel appliances must be cleaned once a year (verify whether a
specific legislation exists in your country).
Failure to regularly inspect and clean the stove increases the probability of a fire occurring in the chimney pot.
In that case, proceed as follows: do not extinguish with water. Empty the pellet hopper. Contact the DEALER after the
incident, before re-igniting.
CAUSE
no mains voltage
too far from stove
remote control batteries are flat
too much soot in exchanger
37
SOLUTIONS
check the power cable connection,
check fuse (on power cable),
check connection of flat cable to
synoptic panel
move closer to the thermal stove
check the battery and if necessary,
replace it
clean the hearth exchanger