ICS-F – Engineering Data
Pump Dimensions and Weights
Dimensions and Weights – Determined by Pump
Pump
Suction NPT
1 x 1¼-5
1¼ x 1½-5
NOTES:
1. Pumps will be shipped with top vertical discharge as standard, for other
orientations, remove casing bolts, rotate to desired position, and tighten
3
" bolts to 24 lbs.-ft.
8
Available Motor and Bedplate Dimensions and Weights
Motor
HA
HB
Frame
56
143T
8
145T
26
182T
10
184T
Dimensions in inches, weight in pounds.
3.50
R
X
58317
CF–8M
4.50
2.00
2.00
5.25
DISCHARGE
5.88
3.50
MAX.
X
SUCTION
58317
CF–8M
3.38
HD
HG
HE
HE
HA
Discharge NPT
1
HD
HE
HF
HG
6.87
3.12
22.38
2.38
7.25
3.75
24
2.75
CP
1.59
W
DISCHARGE
2.00
SUCTION
2.88
L
3.25
1
NPT (OPTIONAL)
4.94
4
CP
3.50
SP ACER COUPLING
1.59
W
COUPLING GUARD,
HL
HF
HB
CP
L
R
W
12.16
5.73
.94
3.01
12.03
5.60
1.06
2.88
2. Dimensions in inches, weight in pounds.
3. Not to be used for construction purposes unless certifi ed.
4. Motor dimensions may vary with motor manufacturers.
HP
Wt. Max.
Shims
1.00
30
1.00
.88
43
.8750
DIA.
.8745
KEYWAY .19 x .12,
.50
4 HOLES .38 DIA.
C
MAX.
3.12
SINGLE PHASE ONL Y
MAX.
7.88
MAX.
4 HOLES
.62 DIA.
HP
HL (Motor Frame)
X
Wt. Max.
56
4.62
38
5.73
4.56
38
5.60
Horsepower – 3500 RPM
Single Phase
Three Phase
ODP
TEFC
ODP
TEFC
½ - 1½ ½ - 1½
½ - 1
½ - 1
2
2
2-3
2
3
3
5
3
5
5
5
140
180
3.85
3.72
Wt.
C Max.
Max.
45
13
45
13.38
52
14.25
63
16.62
112
18.12
9

Publicidad