Programming; Principle - Balluff BTL6-A301 Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL6-A/G301-M_ _ _ _-A1-S115
Micropulse AT Transducer in round profile housing
6

Programming

6.1

Principle

The transducer should be connected
to the controller. All settings are made
with one or two magnets within the
permissible measuring range.
In programming mode the outputs are
used as feedback and status
indicators. They should not be used
for machine control.
Programming is accomplished using
the programming inputs La and Lb.
An LED next to the connector is
provided for programming assistance.
The programming inputs
may only be connected to
Pin 2 (0 V
), not
(output)
Pin 6 (GND).
You can select from between two
operating modes, "Single-Position"
and "Differential". ➥ ➥ ➥ ➥ ➥ Section 6.4
The zero and span as well as the
output slope can be programmed
separately for each output. At least
one magnet must be located within
the stroke range for programming. To
program Output 2 there must be 2
magnets within the stroke range.
Note: The magnet which is closer to
the zero point mark is assigned to
Output 1. If there is only one magnet
within the permissible stroke range, it
is automatically assigned to Output 1.
This applies also if Magnet 1 leaves
the permissible stroke range. Then
Output 1 jumps to the value of Mag-
net 2 and Output 2 provides the error
message.
Operating mode
Programming mode
Outp. 1
selected
Place magnet in
desired position
Set
Set
span
zero
Fig. 6-1: Principles of programming
Leaving
programming mode
Outp. 2
selected
Set
Set
zero
span
> 100 s
Time out
Operating
mode
7
english

Publicidad