Programming Output 2 - Balluff BTL6-A301 Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL6-A/G301-M_ _ _ _-A1-S115
Micropulse AT Transducer in round profile housing
6
Programming (cont.)
6.3

Programming Output 2

Activate Programming mode:
Programming input
La or Lb = "on" until LED comes on
(4 s < t < 8 s)
BTL is in Programming mode:
"Error message" on both outputs
(10.5 V).
Select Output 2:
1) Programming input Lb = "on" until
LED constant on (4 s < t < 8 s)
Output 2 selected, both outputs
provide the current position value.
a) Set zero
1) Place Magnet 2 at desired zero
point.
2) Programming input La = "on" until
LED stays on (4 s < t < 8 s)
Zero for Output 2 programmed:
➔ see also: Programming mode
b) Set span
1) Place Magnet 2 at desired end
point.
2) Programming input Lb = "on" until
LED stays on (4 s < t < 8 s)
Span for Output 2 programmed:
➔ see also: Programming mode
If the value of the zero point
is further from the zero
point marking than the end
point, the output slope is
automatically set to falling.
Zero = 100 % and
Span = 0 % of output value.
BTL6-A/G301... with 2 magnets in the stroke range
4 s < t <8 s
4 s < t <8 s
4 s < t <8 s
Lb
4 s < t <8 s
Fig. 6-3: Programming Output 2
Operating mode
/ Lb
La
Programming mode
Lb
La
Programming mode
La = on ➔ Programming input La to 0 V
Lb = on ➔ Programming input Lb to 0 V
Flash time Code
On : Off
LED off
LED on
0.05 s : 0.05 s
LED
flashing
rapidly
LED on
0.15 s : 0.15 s
LED
flashing
slowly
LED on
0.05 s : 0.05 s
LED
flashing
rapidly
LED on
0.05 s : 0.05 s
LED
flashing
rapidly
(output)
(output)
9
english