Description Of The Hood - ELICA STONE WH/A/33 Montaje Y Modo De Empleo

Ocultar thumbs Ver también para STONE WH/A/33:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45

Description of the hood

Fig. 1
1. Control panel
2. Grease filter
3. Grease filter release handle
4. Halogen lamp
5. Vapour screen
6. Telescopic chimney
7. Air outlet (used for filter version only)
8. point lighting (only for the model in Fig. 1G)
Operation
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
Functioning – Model with Keyboard
B
D
A
C
A. on/off light switch
B. on/off aspiration switch and minimum power selection
B+C. medium power selection aspiration switch
B+D. maximum power selection aspiration switch
a
b-c-d-e
a b-c d
e
f
a. ON/OFF lighting
b. OFF motors
c. - d. - e. Minimum suction power (c.), medium (d.),
maximum (e.).
f. Operation warning light (where present).
Note: Some models only possess one suction Power.
Attention: the models with an electric valve are supplied with 3
keys:
(a) Light ON/OFF, (b) Electric Valve Closure and (c) Opening.
a
b-c-d-e
a b c
d e
Functioning - 5-key electronic model
O
1 2 3
F C
1
2 3 4
1.
Motor OFF button
2.
ON button and motor speed selection button 1 - 2 - 3 - 1 -
2 - . . . .
3.
Speed 1 LED
4.
Speed 2 LED and metal grease filter saturation LED (in
this latter case, the LED will flash - See instructions on
grease filter cleaning).
Once the grease filters have been cleaned, press button
1 for about 3 seconds until you hear the acoustic signal
(beep): the LED 4 will now stop flashing.
5.
Speed 3 LED and active carbon filter saturation LED (in
this latter case, the LED will flash - See instructions on
active carbon filter replacement).
Once you have replaced the charcoal filter, press button
1 for about 3 seconds until you hear the acoustic signal
(beep). LED 5 will now stop flashing.
Warning!
The active carbon filter saturation LED is not activated.
In order to activate the active carbon filter saturation
indicator, press buttons 2 and 7 simultaneously for 3
seconds. Initially, only LED 4 will flash, then after the 3
seconds have passed, LED 5 will also start flashing,
indicating that the active carbon filter saturation control
system is active.
To switch off the system, re-press the same two buttons:
after 3 seconds LED 5 will stop flashing and the device
will be switched off.
6.
Intensive speed LED
7.
Intensive speed ON switch
This speed should be used when the concentration of
cooking fumes or odours is particularly strong (for
example when frying, cooking fish etc.).
The fast speed will run for about 5 minutes and then
return to the speed previously set automatically (1, 2 or
3), or switch off if no speed was selected.
To turn off the fast speed, before the end of the 5
minutes, press button 1 or button 2.
8.
OFF lamp button
9.
ON lamp button
If the hood fails to operate correctly, briefly disconnect it from
the mains power supply for almost 5 sec. by pulling out the
plug. Then plug it in again and try once more before
contacting the Technical Assistance Service.
19
O
5 6 7
8
I
9

Publicidad

Tabla de contenido
loading