Water Supply And Drain Connections - Hoshizaki FM-1000AKE Manual De Instalación

Ocultar thumbs Ver también para FM-1000AKE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
* Usually an electrical permit and services of a
licensed electrician are required.
[FM-1000, 600]
* If the supply cord and/or the plug should need to
be replaced, it should only be done by a qualified
service engineer.
* The fixed wiring must incorporate a means for
disconnection from the supply having a contact
separation of at least 3 mm in all poles.
[FM-750, 480, 300, 170]
* If the supply cord is damaged, it must be
replaced by a special cord or assembly available
from the manufacturer or its service agent.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead
of this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
The wire which is coloured Green-and-Yellow
must be connected to the terminal in the plug
which is marked with the letter E or by the symbol
or coloured Green or Green-and-Yellow. The
wire which is coloured Blue must be connected
to the terminal which is marked with the letter N
or coloured Black. The wire which is coloured
Brown must be connected to the terminal which
is marked with the letter L or coloured Red.
* Should the socket outlets in the installation site
not be suitable for the plug supplied with your
product, the plug must be removed (cut off if it is
moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the
power supply cord, it must be disposed of. There
should be no attempt to reuse it. Inserting such a
plug into a socket elsewhere presents a serious
risk of electrical shock.
* The non-rewirable plug must never be used
without a fuse cover being fitted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer's
reference number stamped on the plug.
Supply of replacement fuse covers can be
obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 12A and approved to
BS 1362.
5. WATER SUPPLY AND DRAIN
CONNECTIONS
WARNING
Connect to potable water supply only.
Note: A plumbing permit and services of a licensed
plumber may be required in some areas.
* The connections to the mains water supply
must be made in accordance with the countries'
current requirements of the Water Supply or
Water Fittings Regulations.
* Water supply pressure should be minimum 0.05
MPa (0.5 bar) and maximum 0.8 MPa (8 bar).
If the pressure exceeds 0.8 MPa (8 bar), use a
proper pressure reducing valve. Do NOT throttle
back the supply tap.
Water Supply
Inlet G3/4
Water Supply Line
Shut-off Valve
Drain Valve
Separate piping to approved
drain. Leave a 5cm vertical
air gap between the end of
each pipe and the drain.
Floor
Fig. 6
3
ENGLISH
Drain Outlet
R3/4
Bin Drain Outlet
3/4 FPT
5cm air gap
Drain

Publicidad

Tabla de contenido
loading

Tabla de contenido