Prepare Installation Space
Combining several Vario devices: The connecting strip VA
420 000/001/010/011 is required for the combination of
several Vario appliances. This is available separately as a
special accessory. Consider additional space
requirement for the connecting strip between the
appliances when making the cut-out (see installation
instructions VA 420 000/001/010/011).
Appliances can also be installed in individual cut-outs,
bearing in mind a minimum distance between the devices
of 2" (51 mm).
When combining several appliances with or without
appliance cover, you can use the appliance extensions
VA 450 110/-401/-600/-800/-900 (depending on
appliance width) to balance out dimension differences.
Drilled Hole for Control Knob
Possible types of installation:
Installation in the front of the base cabinet
▯
Installation in the countertop next to the appliance
▯
Installation in the countertop in front of the appliance
▯
Note: Follow the installation instructions provided for the
control knobs.
8
Ventilation
To guarantee that the appliance works correctly, the
cooktop MUST be sufficiently ventilated.
Since the ventilation in the lower section of the appliance
requires a sufficient supply of fresh air, the cabinet must
be designed accordingly. The following is required for
this:
A minimum clearance between the rear of the
▯
cupboard and the kitchen wall, and between the
surface of the worktop and the upper area of the
drawer.
An opening at the top to the rear of the cupboard.
▯
If the minimum clearance of
▯
provided at the rear of the cupboard, you must create
an opening on the underside.
/
inch (20 mm) is not
25