Prepare Installation Space; Cutting Out Countertop; Ventilation - Gaggenau VI 263 620 Instrucciones De Instalación

Ocultar thumbs Ver también para VI 263 620:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Prepare Installation Space

P r e p a r e I n s t a l l a t i o n S p a c e
C reate the cut-out in the countertop according to the
installation diagram. The angle of the cut surface to the
countertop must be 90°.
The lateral cut-out edges must be flat in order to ensure
that the retaining springs are positioned properly on the
appliance. With multi-layered countertops, secure strips
laterally in the cut-out if necessary.
After creating cut-out, remove shavings. Seal cut
surfaces in a heat- and water-resistant manner.
Observe minimum distance between device underside
and cabinet surfaces of
The worktop into which the cooktop is installed must be
heat-resistant up to 140° F (90 °C).
The worktop must be reinforced if it is less than
(20 mm) thick.
If the thickness of the worktop into which the cooktop is
installed does not comply with the specifications,
reinforce the worktop using a fire- and water-resistant
material until it reaches the minimum thickness.
Otherwise, sufficient stability cannot be assured.
The worktop into which the cooktop is installed should
withstand loads of approx. 133 lbs (60 kg).
Confirm the cooktop is level only after it has been
installed.
3
/
" (10 mm).
8
13

Cutting out countertop

/
inch
16
Combining several Vario appliances: Consider additional
space requirement for the connecting strip VV 200 when
making the cut-out. Appliances can also be installed in
individual cut-outs, if a minimum clearance of 1½"
(40 mm) between the appliances is observed.
Installation accessories
VV 200 010
VV 200 020
Use the accessories only as indicated. The manufacturer
assumes no liability for incorrect usage of the
accessories.

Ventilation

To guarantee that the appliance works correctly, the
cooktop MUST be sufficiently ventilated.
Since the ventilation in the lower section of the appliance
requires a sufficient supply of fresh air, the cabinet must
be designed accordingly. The following is required for
this:
Prepare Installation Space
Stainless steel connection strip for
combining with other Vario 200
appliances
Black connection strip for combining
with other Vario 200 appliances
en-us
7

Publicidad

Tabla de contenido
loading

Tabla de contenido