5
Setting of address and parameter
5.1
Parameter enabling
During normal operation parameters can only be viewed. If parameters are to be changed,
the ON menu item in the Parameter -> Parameter handling -> Parameter enable
menu must be activated. To do this, proceed as follows:
Parameter
Parameter handling
PROFINET
Maximum position value
I/O
Other
Parameter handling
o Parameter enabling
o
Password
Parameters to default
Parameter enabling
o
OFF
o ON
Parameter enabling
o
OFF
ON
Leuze electronic
In the main menu, press the enter button to enter the Parameter
menu.
Use the
menu item.
Press the enter button to enter the Parameter handling
menu.
In the Parameter handling menu, use the
the Parameter enabling menu item.
Press the enter button to enter the Parameter enabling
menu.
In the Parameter enabling menu, use the
the ON menu item.
Press the enter button to switch on parameter enabling.
The PWR LED illuminates orange; the display is inverted. You can
now set the individual parameters on the display.
Press the ESC button twice to return to the Parameter menu.
ESC
ESC
AMS 3xx
buttons to select the Parameter handling
i
buttons to select
buttons to select
11