USING THE BEARING BUDDY COIL™
Function: The Bearing Buddy Coil™ (6) is used to free a race from an axle housing, frozen O² Sensors, remove ball
joints, & tie-rod ends.
A. Expanding a piece to remove an interlocking part.
Step 1 Perform the "Preparation for Use" instructions.
Step 2 Insert one end of the Bearing Buddy Coil into one of the electrodes and tighten Twist-Lock™.
Step 3 Wrap the coil at least 3 times around the work piece to be expanded.
The more coil winds you have the faster it will heat.
Tip:
Step 4 Insert the other end into the remaining open electrode and tighten the Twist-Lock™.
Step 5 Push the activation switch to operate the HAND-DUCTION.
Step 6 Heat until expanded enough to remove the race.
Step 7 Release the activation switch and loosen Twist-Lock™ to remove the Bearing Buddy Coil.
USING THE MINI-PAD™ (OPTIONAL)
Function: The Mini-Pad™ (8) is used for removing stickers, decals, graphics, emblems, small body side moldings, and
pin striping.
A. Removing Bonded on parts.
Step 1 Perform the "Preparation for Use" instructions.
Step 2 Insert both Mini-Pad ends into the electrodes and tighten Twist-Lock™.
Step 3 Push the activation switch to operate the HAND-DUCTION.
Step 4 Apply the Mini-pad to the end of the desired part to be removed for a couple seconds. Once you are
able to peel the start of the part off, you will have an area you can pull on to keep outward pressures going.
Re-apply the Mini-Pad to the part, working it down the part while keeping outward pressure until the part
is completely removed.
TROUBLE SHOOTING
The HAND-DUCTION tool is designed with protection circuits that inhibit operation of the inverter (1) under specific conditions.
If the activation switch (9) is operated without a work coil attached or the coil is intermittently shorted or opened the
inverter (1) will shut down and the status indicator LED (14) will turn Red.
Either of these faults will lock out inverter operation for approximately 3 seconds. The Red status indicator LED (14) will
dim over the lock out time until it goes out.
If the tools inverter electronics overheats the tool will immediately shut down.
The Red status indicator LED (14) will remain lit until the fan has cooled the electronics sufficiently to reset the thermal limit
switch plus 3 seconds.
The tool is fully operational when the fan stops running.
Operation of the tool for extended periods or using too many turns on a Bearing Buddy™ (6) or U-Form (7) coil can result
in overheating.
This operation is independent of the illumination LED (White) (12). If the illumination LED (12) cannot be activated or the
tool stops operating without a status indication, the tool has lost power.
Verify that the AC outlet power is functioning. If an extension cord is used with this tool be sure it is appropriately rated
and is not damaged.
The status indicator LED (14) will illuminate Red if the input voltage is too high. Care must be taken when using a
generator to provide proper operating voltage.
If the problem does not correct itself or persists call your dealer.
Extension cord, if used should be at least 14-AWG for a 25 foot cord or at least 12-AWG for a 50 foot cord.