Additional Switching Output; Networked Operation - Gaggenau AL 400 721 Instrucciones De Instalación

Ocultar thumbs Ver también para AL 400 721:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9
Fasten the connecting studs to the appliance.
Secure the exhaust air pipe to the connecting
piece and seal appropriately.
Connection with round pipe.
Note: If using an aluminum pipe, smooth the
connection area beforehand.
10 Connecting the connection cable: Firmly insert
the control cable from the control unit into the
appliance and the fan module. The plug must
snap into place. Connect the control unit and fan
module to the mains and check that they work
correctly. If the appliance does not work, check
that the connection cable is positioned correctly.
Note: The X1 and X2 connection sockets are
identical.

Additional switching output

Work must only be carried out on the additional
switching output by a qualified electrician in
accordance with the country-specific requirements
and standards.
The appliance has an additional switching output X16
(potential-free contact) that can be used to connect
other appliances, such as a ventilation system that is
available at the installation site. The contact is closed
when the fan is switched on, and is opened when the
fan is switched off.
The switching output is located under a cover.
Maximum switching power 30 V/1 A (AC/DC). The
signal that is connected to the contact must
correspond to class of protection 3.

Networked operation

Several appliances can be networked together. The
light and fan on each of the appliances are operated
synchronously.
Connect the appliances in series via the connector
sockets X1 and X2 (equal value). The sequence of the
networking does not have any effect. If the enclosed
network cables are too short, use a commercially
available network cable (min. Cat. 5, shielded).
Maximum number of networked appliances: 20. Total
length of all of the network cables: 40 m. During the
initial installation, a qualified electrician must check
that the system functions correctly.
If one of the networked appliances fails (power
interruption, network cable disconnected), this leads
to the fan function being blocked for the entire
system. All of the buttons on the appliance flash.
When changing the configuration, the system must be
re-initialized:
1
Unscrew the cover plate.
2
Press and hold the reset button until both LEDs
light up continuously (approx. 5 seconds). Then
release the button within 5 seconds.
3
Screw on the cover plate.
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Al 400 791

Tabla de contenido