LED indicator
The operation mode of the Soladin is displayed by
means of a LED indicator at the front side of the
housing. In normal operation it flashes yellow: the
longer the LED illuminates yellow, the more power
is converted.
If the irradiation of the PV-modules is insufficient, for
instance
at
night,
automatically. When switched off, the LED indicator
is off.
Indication of the LED
LED is off
LED is off
Yellow blinking
Slow blinking long red
pulses
▬ ▬ ▬ ▬ ▬ ▬
Fast blinking long red
pulses
▬▬▬▬▬▬▬▬
Uninterrupted red
Red blinking 1 time
• •
• •
• •
• •
Red blinking 2 times
• • •
• • •
• • •
Red blinking 3 times
• • • •
• • • •
Red blinking 4 times
• • • • •
• • • • •
Red blinking 5 times
• • • • • •
Red blinking 6 times
• • • • • • •
Red blinking 7 times
Table 2
8
the
Soladin
switches
Meaning
Insufficient irradiation
No power from the
PV modules
Normal operation
Reclosure time
Restart time lag
No grid voltage
Solar voltage too low
Solar voltage too
high
AC grid voltage too
high
AC grid voltage too
low
Grid frequency too
high or too low
Internal temperature
too high
NTC error
USERS MANUAL SOLADIN 600
Failures
As long as the indication LED isn't illuminated red,
no failure is detected: the Soladin is operating
normally. If an error occurs, it is detected by the
apparatus itself: the LED indicator turns red. See
table 2.
Consult an installer, if you cannot solve the problem
by means of the table below.
off
NOTE: during sunrise or sunset a low Solar
voltage is detected by Soladin, indicated by
a red blinking LED indicator. This is a normal
situation
What to do?
Nothing. The Soladin operates normally, but irradiation of the PV
modules is insufficient (for instance during night time)
Consult an installer if the LED indicator is off during daytime.
The wiring between the PV modules and the Soladin might be
defective. Check for loose connections or incorrect polarity.
Nothing. The Soladin operates normally. The longer the LED
illuminates yellow, the more power is converted.
Nothing. After the Soladin was (re)connected to the AC grid, it checks
the quality of the AC grid before it starts operating normally. This may
take up to 5 minutes.
Nothing. A system check is carried out during sunrise. This may take
up to 15 seconds before the Soladin starts operating normally.
Plug the AC-plug of the Soladin into the wall socket; check the fuse in
the meter cupboard.
Nothing; normal condition during sunrise and sunset.
Consult an installer if the problem remains while irradiation of the PV
modules is sufficient.
Error in the PV installation. Are the specifications of the PV modules
in accordance with the Soladin?
Consult an installer. Error in the PV installation. Are the specifications
of the PV modules in according with the Soladin?
Check the grid connection.
Check the grid connection.
Check the grid connection.
Air flow of the Soladin may not be obstructed. If the problem remains,
switch off the Soladin by removing the AC-plug from the wall-socket
and consult an installer.
Consult an installer for repair of a defective safety device in the
Soladin.